Be a better neighbor. Sign up for EveryBlock to follow and discuss neighborhood news.

Sign up for free →

Added Jun 13 2018

Violation date
June 11, 2018
Id
4416608
Violation code
CN197087
Violation status
COMPLIED
Violation description
CARB MONOX DETECT IN RESID
Violation comments
MISSING
Violation ordinance
Install carbon monoxide detector within 40 feet of every sleeping room in residential structure. (13-64-190, 13-64-210) A carbon monoxide detector is needed whenever there is a heating appliance on the premises that burns fossil fuel such as gas, oil, or coal, or air that is circulated through a heat exchanger. Install according to manufacturer instructions. A hard wired model requires an electrical wiring permit. In a single family residence, be sure the detector is on or below the lowest floor with a place to sleep. In a multiple dwelling residence heated by a boiler, install a detector in the same room as the boiler. Otherwise, each apartment follows single family guidelines. The owner is responsible for installation and written instructions, the tenant for testing, maintenance, and batteries.

Posted to 5131 S ROCKWELL ST

This was posted to 5131 S ROCKWELL ST

What's the news in your neighborhood? Search for your ZIP code:

e.g. 60615